Load-Bearing Walls · LVL Headers · Sistered Joists · Additions

Structural Framing Serving Greater Boston

Structural framing carpentry serving Dedham and Greater Boston. Load-bearing walls, LVL headers, sistered joists, additions, wall openings — all built to Massachusetts State Building Code.

Request Estimate →
Structural framing on an addition — Crafted Edge Carpentry, Greater Boston MA

What structural framing work looks like

Structural carpentry is the framing that holds the house up. Load-bearing walls, floor joists, ceiling joists, rafters, and the beams and headers that carry loads across openings. When any of that fails — sagging floors, doors that won't close, cracked drywall over an opening — it needs a carpenter who understands how loads move through a building.

Most of the structural work we do falls into a few categories: sistering or replacing floor joists that have sagged or rotted, adding or resizing headers over new door and window openings, opening up walls between rooms, framing dormers and additions, and repairing rot in rim joists, sill plates, and load-bearing walls.

Every one of these jobs starts with figuring out what's carrying what. Before we touch a wall or a joist we need to know where the load goes — down to the foundation, out to bearing points, or into a beam. We don't cut structural members without understanding the load path.

Materials we frame with

For any beam or header, we do a span calculation — either using the IRC span tables (referenced in Massachusetts code) or working from an engineer's spec on complex projects. Guessing at beam sizes is not something we do.

Massachusetts building code and permits

Structural work almost always requires a building permit in Massachusetts. That includes adding or resizing headers, changing floor framing, opening bearing walls, adding dormers or additions, and most rot repair on structural members.

All structural work is built to Massachusetts State Building Code (780 CMR, 10th Edition). That means proper joist spacing and spans, code-compliant beam sizes, correct connection hardware, and — for anything involving bearing walls or significant openings — sometimes a stamped engineer's drawing.

For complex structural changes (removing a load-bearing wall, adding a second-story addition, seismic work), we bring in a structural engineer to design the connections. The engineer's stamp goes on the permit application. This is standard practice and it's how the work gets approved.

Common structural problems in Boston-area homes

★★★★★

"I called Alexei and he was fantastic from start to finish. He took the time to give me a thorough walk-through of exactly how he would approach the job and the steps he'd take to ensure a high-quality, long-lasting repair. He was completely transparent about materials and labor costs. No surprises at all."

Marshall Davis · Google Review

Ready to talk about your project?

Request an estimate or call us directly. We respond within 24 hours.

Request Estimate Call (617) 877-1450